Dilution Calculator (C1V1 = C2V2)
Fill in the fields and press Calculate to see the result.
About the Dilution Calculator (C1V1 = C2V2)
Work out how much stock solution and diluent you need for a dilution with C1V1 = C2V2. Enter the concentration of the stock, the final concentration you want and the final volume: the calculator gives the volume of stock to take, the volume of diluent to add and the dilution factor.
How it is calculated
C1 × V1 = C2 × V2
Diluting does not change the amount of solute, so the stock concentration times the stock volume equals the final concentration times the final volume. The stock volume is therefore V1 = C2 × V2 / C1, and the rest of the final volume, V2 − V1, is diluent (water, buffer or medium). The dilution factor is C1 / C2.
C1 and C2 can be in any unit – molar, mg/mL, percent or X for buffers – as long as both are in the same one.
Example
To make 50 mL of 1X buffer from a 10X stock: V1 = 1X × 50 mL / 10X = 5 mL. Take 5 mL of the stock and add 45 mL of water: a 1:10 dilution.
Frequently asked questions
What does a 1:10 dilution mean?
One part of stock in ten parts of final volume (dilution factor 10), for example 1 mL of stock plus 9 mL of diluent. Some labs write 1:9 for the same mix (stock to diluent), so check which convention a protocol uses.
Can I use mass concentrations or percentages?
Yes. C1V1 = C2V2 works with any concentration unit, as long as C1 and C2 are in the same one.
How do I make a serial dilution?
Repeat the same dilution several times, each time starting from the previous tube: three successive 1:10 dilutions give 1:1,000.